Turntable tracking force: identify, set and verify
Set tracking force from the specifications of the cartridge and stylus actually fitted, using the tonearm’s own procedure. Balancing the arm, zeroing an indicator and applying force are different operations. Anti-skate is a separate adjustment. Do not copy a universal number, assume a replacement cartridge uses the original setting, or treat the dial as an independent measurement.
Published 4 Oct 2026
Identify the installed cartridge and arm
is the downward force applied through the stylus during playback. The correct setting comes from the actual cartridge and fitted stylus, together with the tonearm's instructions. The turntable's model name alone is not enough when parts have been changed.
Write an identity card before adjusting anything:
- Deck and tonearm: exact model and whether force adjustment is user-accessible.
- Cartridge and stylus: both identities, including replacement parts.
- Documentation: applicable arm procedure, recommended force and permitted range.
- Anti-skate: the arm manufacturer's method and any cartridge-specific guidance.
Two specifications show why there is no universal target. The AT-VM95E specifies 1.8–2.2 g with 2.0 g as its standard setting. The Ortofon 2M Blue specifies 1.6–2.0 g with 1.8 g recommended. These examples do not establish that either cartridge fits your arm. Use the setting for the installed parts.
Understand balance, zero and applied force
On an adjustable counterweight arm, balancing establishes a reference condition. Zeroing the numbered indicator records that reference. Moving the counterweight then applies the intended force. The exact mechanism and manipulation differ between arms; a preset or nonadjustable arm may not use this sequence at all.
The distinction is clear in the AT-LP120XUSB manual, page 7. For that model with its supplied AT-VM95E, its sequence is:
- Follow the illustrated balance procedure while controlling the headshell, then secure the arm on its rest.
- Keep the counterweight stationary while aligning the indicator's zero.
- Move the counterweight and indicator together to the supplied cartridge's 2.0 g setting.
- Apply that manual's separate anti-skate instruction.
Use the linked manual for handling, protector removal and movement directions. On this mechanism, rotating only the numbered ring changes the indication without setting the force. A matching number on the ring is therefore not proof that the earlier steps were performed correctly.
Keep the arm under control throughout. Never drag the stylus across the platter or record while making adjustments. Stop if you cannot identify the fitted parts or handle the arm without uncontrolled movement.
Set anti-skate by the applicable instructions
counteracts the inward turning tendency associated with stylus/groove friction. Ortofon's FAQ explains that stylus and groove conditions affect it. It is a separate adjustment from vertical tracking force.
The named Audio-Technica setup uses equal numerical anti-skate and tracking-force indications. That is its setup instruction, not a universal physical equality between two forces or a prescription for every tonearm. Follow the instructions for your arm and cartridge rather than copying another dial position.
Keep an honest verification record
Record the recommended setting, permitted range, final dial indication, date and fitted parts. If you obtain an independent gauge reading, record the gauge and its reading separately. Use that gauge's calibration and placement instructions together with the arm manual; an arbitrary measuring height or an uncalibrated display does not establish the result.
A useful record distinguishes “indicator set to the recommended value” from “force independently measured.” Neither statement by itself certifies cartridge alignment, arm geometry or stylus condition.
Recheck setup after cartridge replacement or relevant mechanical changes. If playback mistracks or distorts, return to identification and the documented setup checks; do not add improvised weight, exceed the cartridge's range or repeatedly play a damaging condition to find a setting by ear. Seek model-specific help when the procedure or condition of the parts is uncertain.
Use the turntable system guide for the rest of the setup and phono versus line for the electrical route.
Sources
- AT-LP120XUSB manual — pages 7 and 13 — Audio-Technica
- AT-VM95E force specification — Audio-Technica
- 2M Blue force specification — Ortofon
- Anti-skating and distortion FAQ — Ortofon
Put it to work in your own system
Pure Neo keeps your hi-fi setup in one place, with the specs of every component side by side.


